How To Repair Macroview Mp712s 17" CRT Monitor

">True enough, there was a crystal clear burnt marked
The complaint for this Macroview mp712s 17”at the center of the main board.
monitor was no power. Once the cover was removedClosely inspection revealed that it was a Fet with the
and power on, you could hear a softpart number of IRF630 (n-channel fet) and it is located
“chip-chip” sound indicating the powerin the s-correction circuit. Looking at the fet from
trying to come out but something had caused it to shutbehind the main board shows that 3 leads has a
down. The LED indicator has no light at all. Just likesevered dry joints. I believe this is the reason as to
troubleshooting any other monitor problems, the firstwhy the fet burnt. Usually when you found a
thing that I do was to look for any burnt marked, loosecomponent that had dry joint, chances are very high
connection at cables, dry joints and burnt components.that it could have dry joints in other area.