| "> | | | | True enough, there was a crystal clear burnt marked |
| The complaint for this Macroview mp712s 17â | | | | at the center of the main board. |
| monitor was no power. Once the cover was removed | | | | Closely inspection revealed that it was a Fet with the |
| and power on, you could hear a soft | | | | part number of IRF630 (n-channel fet) and it is located |
| âchip-chipâ sound indicating the power | | | | in the s-correction circuit. Looking at the fet from |
| trying to come out but something had caused it to shut | | | | behind the main board shows that 3 leads has a |
| down. The LED indicator has no light at all. Just like | | | | severed dry joints. I believe this is the reason as to |
| troubleshooting any other monitor problems, the first | | | | why the fet burnt. Usually when you found a |
| thing that I do was to look for any burnt marked, loose | | | | component that had dry joint, chances are very high |
| connection at cables, dry joints and burnt components. | | | | that it could have dry joints in other area. |